Interacoustics MT10 Middle Ear Analyser Tympanometer

SKU
AUDI004
Direct from Supplier
£3,594.00
The Interacoustics MT10 Tympanometer is built to accommodate modern health-care settings where fast and reliable testing is paramount.

The Interacoustics MT10 audiometer and printer is built to accommodate modern health-care settings where fast and reliable testing is paramount.

The MT10 audiometer is well suited for diagnostic use as tympanograms and optional reflex responses are all recorded in great detail. With the MT10 you can detect
otitis media, a perforated eardrum, cholesteotomas and certain neurological disorders.  You can also check tympanostomy tubes and follow up on post medical treatments.

Four different reflex tests may be performed per ear using either fixed or automatic intensity selection.  The test is carried out at the correct pressure level and the actual reflex characteristics are displayed on the screen for the operator to view and interpret.

• 4 frequencies (500, 1000, 2000, 4000 Hz)
• Single or multiple dB level threshold search
• Auto detection of threshold

The Interacoustics MT10 tympanometer can hold test results of up to 30 patients in its memory. This makes it possible to screen a large group of patients and print out the data at a later time.

Specifications

Instrument type:  Screening tympanometer
Analysis performed:  Compliance peak level (in ml). Pressure of same; Gradient (in daPa); Ear Canal Volume (ECV) @ 200 daPa.
Probe tone levels and accuracy:  226Hz +/-2%; 85dB SPL +/-2dB over range 0.2ml to 5 ml.
Pressure levels and accuracy:  +200daPa to -400 daPa +/-10daPa or +/-10% (whichever is larger) over range.
Ear volume measurement range and accuracy:  0.2ml to 5ml +/-0.1ml or +/-5% (whichever is larger) over entire range.
Sweep speed:  Typically 200-300daPa/sec; dependant on ear&cavity volume.
Pressure limits (safety cutout):  +600 to -800daPa
Number of samples stored:  100 per tympanogram

Optional:
Reflex measurements
Measurement modes:  Ipsilateral optional
Reflex tone levels and accuracy:  500Hz, 1kHz, 2kHz, 4kHz
Frequency:   +/-2%, configurable over range 70dB to 100dB HL (4kHz restricted to 95dBHL) +/-2dB, referenced to 2ml calibration volume; Compensates for measured ear volume.
Reflex measurement range and accuracy:  0.01ml to 0.5ml +/-0.01ml configurable in 0.01ml steps.
Number of reflex levels: Four: 100dB with 5dB or 10dB steps; 95dB, 90dB or 85dB with 5dB steps.
Reflex analysis:  Reflex pass/fail at each level tested; Maximum amplitude of each reflex (seen on printed report and PC report); Pressure at which reflex was performed.
Pressure used for reflex measurement:  Pressure at Tympanogram peak, or 0daPa (Always and Prompt Before Each Test modes)
Reflex level cut-off:  Optionally, Auto-stop when reflex found.
Reflex threshold detection:  Configurable 0.01-0.50ml in 0.01ml increments.
Reflex tone duration:  0.6 seconds.
Number of records stored in Patient Database:  30
Data storage:  Any recording can be stored once the tympanogram is viewed. Patient Initials (A-Z, 0-9, “-“) must be entered before storage.
Data held:  Patient Initials, Tympanogram and Reflex graphs and analysis for Left Ear and/or Right Ear, Time and Date of recording, which ears were tested, whether or not the record has been printed and /or sent to a PC, parameters printed and/or sent to a PC, parameters used for analysis, 128 bit Globally Unique Idenfitier (GUID).
Display mode:  Records listed in reverse chronological order (latest first), with indication of date stored as described above.

Real Time Clock

Time stamps:  Time and date stamp applied to all recordings, and to the last calibration date.
Backup power supply:  >30 days without main batteries fitted.


Languages
Operating languages:  English, German or French

Printing
Supported printer:  Sanibel MPTII.
Interface:  Infra-red, IrDA hardware, 9600 baud.
Information printed:  Space for patient and clinician’s details, Tympanogram analysis parameters, Tympanogram, Reflex analysis parameters, Reflex graph, Serial Number of device, Last and Next Due Calibration dates.


Serial Interface to PC
Interface:  OBEX (Object Exchange) service running on top of IrDA stack. Auto-selects rate between 9600 – 115200 baud.
Information sent:  Patient header, full left or right ear data.


Power Supply
Battery types:  4 Alkaline AA Cells or; 4 NIMH rechargeable batteries which must be larger than 2.3Ah capacity.
Warm-up period:  None at room temperature.
Number of recordings from one set of cells:  Approx. 200 (Alkaline AA)
Auto power-off delay:  90 or 180 seconds.
Idle current:  70mA
Current while testing:  230mA


Physical
Display:  128x64 pixels / 8 lines of 21 characters
Dimensions:  190mm long x 80mm wide x 40mm high excluding probe, 225mm long including probe.
Weight (without batteries):  285g
Weight (with batteries):  380g

Included Parts

  • 4 x 1.5V ‘AA’ Batteries
  • Set of disposable ear-tips
  • Printer
  • Instructions for Use
  • Calibration certificate
  • Warranty card

 

**Please allow 7 days for delivery**

TypeTympanometer
ManufacturerInteracoustics
MPN8101355
Warranty2 Years

The Interacoustics MT10 audiometer and printer is built to accommodate modern health-care settings where fast and reliable testing is paramount.

The MT10 audiometer is well suited for diagnostic use as tympanograms and optional reflex responses are all recorded in great detail. With the MT10 you can detect
otitis media, a perforated eardrum, cholesteotomas and certain neurological disorders.  You can also check tympanostomy tubes and follow up on post medical treatments.

Four different reflex tests may be performed per ear using either fixed or automatic intensity selection.  The test is carried out at the correct pressure level and the actual reflex characteristics are displayed on the screen for the operator to view and interpret.

• 4 frequencies (500, 1000, 2000, 4000 Hz)
• Single or multiple dB level threshold search
• Auto detection of threshold

The Interacoustics MT10 tympanometer can hold test results of up to 30 patients in its memory. This makes it possible to screen a large group of patients and print out the data at a later time.

Specifications

Instrument type:  Screening tympanometer
Analysis performed:  Compliance peak level (in ml). Pressure of same; Gradient (in daPa); Ear Canal Volume (ECV) @ 200 daPa.
Probe tone levels and accuracy:  226Hz +/-2%; 85dB SPL +/-2dB over range 0.2ml to 5 ml.
Pressure levels and accuracy:  +200daPa to -400 daPa +/-10daPa or +/-10% (whichever is larger) over range.
Ear volume measurement range and accuracy:  0.2ml to 5ml +/-0.1ml or +/-5% (whichever is larger) over entire range.
Sweep speed:  Typically 200-300daPa/sec; dependant on ear&cavity volume.
Pressure limits (safety cutout):  +600 to -800daPa
Number of samples stored:  100 per tympanogram

Optional:
Reflex measurements
Measurement modes:  Ipsilateral optional
Reflex tone levels and accuracy:  500Hz, 1kHz, 2kHz, 4kHz
Frequency:   +/-2%, configurable over range 70dB to 100dB HL (4kHz restricted to 95dBHL) +/-2dB, referenced to 2ml calibration volume; Compensates for measured ear volume.
Reflex measurement range and accuracy:  0.01ml to 0.5ml +/-0.01ml configurable in 0.01ml steps.
Number of reflex levels: Four: 100dB with 5dB or 10dB steps; 95dB, 90dB or 85dB with 5dB steps.
Reflex analysis:  Reflex pass/fail at each level tested; Maximum amplitude of each reflex (seen on printed report and PC report); Pressure at which reflex was performed.
Pressure used for reflex measurement:  Pressure at Tympanogram peak, or 0daPa (Always and Prompt Before Each Test modes)
Reflex level cut-off:  Optionally, Auto-stop when reflex found.
Reflex threshold detection:  Configurable 0.01-0.50ml in 0.01ml increments.
Reflex tone duration:  0.6 seconds.
Number of records stored in Patient Database:  30
Data storage:  Any recording can be stored once the tympanogram is viewed. Patient Initials (A-Z, 0-9, “-“) must be entered before storage.
Data held:  Patient Initials, Tympanogram and Reflex graphs and analysis for Left Ear and/or Right Ear, Time and Date of recording, which ears were tested, whether or not the record has been printed and /or sent to a PC, parameters printed and/or sent to a PC, parameters used for analysis, 128 bit Globally Unique Idenfitier (GUID).
Display mode:  Records listed in reverse chronological order (latest first), with indication of date stored as described above.

Real Time Clock

Time stamps:  Time and date stamp applied to all recordings, and to the last calibration date.
Backup power supply:  >30 days without main batteries fitted.


Languages
Operating languages:  English, German or French

Printing
Supported printer:  Sanibel MPTII.
Interface:  Infra-red, IrDA hardware, 9600 baud.
Information printed:  Space for patient and clinician’s details, Tympanogram analysis parameters, Tympanogram, Reflex analysis parameters, Reflex graph, Serial Number of device, Last and Next Due Calibration dates.


Serial Interface to PC
Interface:  OBEX (Object Exchange) service running on top of IrDA stack. Auto-selects rate between 9600 – 115200 baud.
Information sent:  Patient header, full left or right ear data.


Power Supply
Battery types:  4 Alkaline AA Cells or; 4 NIMH rechargeable batteries which must be larger than 2.3Ah capacity.
Warm-up period:  None at room temperature.
Number of recordings from one set of cells:  Approx. 200 (Alkaline AA)
Auto power-off delay:  90 or 180 seconds.
Idle current:  70mA
Current while testing:  230mA


Physical
Display:  128x64 pixels / 8 lines of 21 characters
Dimensions:  190mm long x 80mm wide x 40mm high excluding probe, 225mm long including probe.
Weight (without batteries):  285g
Weight (with batteries):  380g

Included Parts

  • 4 x 1.5V ‘AA’ Batteries
  • Set of disposable ear-tips
  • Printer
  • Instructions for Use
  • Calibration certificate
  • Warranty card

 

**Please allow 7 days for delivery**

Only registered users can write reviews. Please Sign in or create an account
TypeTympanometer
ManufacturerInteracoustics
MPN8101355
Warranty2 Years

The Interacoustics MT10 audiometer and printer is built to accommodate modern health-care settings where fast and reliable testing is paramount.

The MT10 audiometer is well suited for diagnostic use as tympanograms and optional reflex responses are all recorded in great detail. With the MT10 you can detect
otitis media, a perforated eardrum, cholesteotomas and certain neurological disorders.  You can also check tympanostomy tubes and follow up on post medical treatments.

Four different reflex tests may be performed per ear using either fixed or automatic intensity selection.  The test is carried out at the correct pressure level and the actual reflex characteristics are displayed on the screen for the operator to view and interpret.

• 4 frequencies (500, 1000, 2000, 4000 Hz)
• Single or multiple dB level threshold search
• Auto detection of threshold

The Interacoustics MT10 tympanometer can hold test results of up to 30 patients in its memory. This makes it possible to screen a large group of patients and print out the data at a later time.

Specifications

Instrument type:  Screening tympanometer
Analysis performed:  Compliance peak level (in ml). Pressure of same; Gradient (in daPa); Ear Canal Volume (ECV) @ 200 daPa.
Probe tone levels and accuracy:  226Hz +/-2%; 85dB SPL +/-2dB over range 0.2ml to 5 ml.
Pressure levels and accuracy:  +200daPa to -400 daPa +/-10daPa or +/-10% (whichever is larger) over range.
Ear volume measurement range and accuracy:  0.2ml to 5ml +/-0.1ml or +/-5% (whichever is larger) over entire range.
Sweep speed:  Typically 200-300daPa/sec; dependant on ear&cavity volume.
Pressure limits (safety cutout):  +600 to -800daPa
Number of samples stored:  100 per tympanogram

Optional:
Reflex measurements
Measurement modes:  Ipsilateral optional
Reflex tone levels and accuracy:  500Hz, 1kHz, 2kHz, 4kHz
Frequency:   +/-2%, configurable over range 70dB to 100dB HL (4kHz restricted to 95dBHL) +/-2dB, referenced to 2ml calibration volume; Compensates for measured ear volume.
Reflex measurement range and accuracy:  0.01ml to 0.5ml +/-0.01ml configurable in 0.01ml steps.
Number of reflex levels: Four: 100dB with 5dB or 10dB steps; 95dB, 90dB or 85dB with 5dB steps.
Reflex analysis:  Reflex pass/fail at each level tested; Maximum amplitude of each reflex (seen on printed report and PC report); Pressure at which reflex was performed.
Pressure used for reflex measurement:  Pressure at Tympanogram peak, or 0daPa (Always and Prompt Before Each Test modes)
Reflex level cut-off:  Optionally, Auto-stop when reflex found.
Reflex threshold detection:  Configurable 0.01-0.50ml in 0.01ml increments.
Reflex tone duration:  0.6 seconds.
Number of records stored in Patient Database:  30
Data storage:  Any recording can be stored once the tympanogram is viewed. Patient Initials (A-Z, 0-9, “-“) must be entered before storage.
Data held:  Patient Initials, Tympanogram and Reflex graphs and analysis for Left Ear and/or Right Ear, Time and Date of recording, which ears were tested, whether or not the record has been printed and /or sent to a PC, parameters printed and/or sent to a PC, parameters used for analysis, 128 bit Globally Unique Idenfitier (GUID).
Display mode:  Records listed in reverse chronological order (latest first), with indication of date stored as described above.

Real Time Clock

Time stamps:  Time and date stamp applied to all recordings, and to the last calibration date.
Backup power supply:  >30 days without main batteries fitted.


Languages
Operating languages:  English, German or French

Printing
Supported printer:  Sanibel MPTII.
Interface:  Infra-red, IrDA hardware, 9600 baud.
Information printed:  Space for patient and clinician’s details, Tympanogram analysis parameters, Tympanogram, Reflex analysis parameters, Reflex graph, Serial Number of device, Last and Next Due Calibration dates.


Serial Interface to PC
Interface:  OBEX (Object Exchange) service running on top of IrDA stack. Auto-selects rate between 9600 – 115200 baud.
Information sent:  Patient header, full left or right ear data.


Power Supply
Battery types:  4 Alkaline AA Cells or; 4 NIMH rechargeable batteries which must be larger than 2.3Ah capacity.
Warm-up period:  None at room temperature.
Number of recordings from one set of cells:  Approx. 200 (Alkaline AA)
Auto power-off delay:  90 or 180 seconds.
Idle current:  70mA
Current while testing:  230mA


Physical
Display:  128x64 pixels / 8 lines of 21 characters
Dimensions:  190mm long x 80mm wide x 40mm high excluding probe, 225mm long including probe.
Weight (without batteries):  285g
Weight (with batteries):  380g

Included Parts

  • 4 x 1.5V ‘AA’ Batteries
  • Set of disposable ear-tips
  • Printer
  • Instructions for Use
  • Calibration certificate
  • Warranty card

 

**Please allow 7 days for delivery**